Application
DCV high voltage divider is applied to measure AC/DC high voltage in metrology department of power system or high voltage test.
Technical parameters
Model | Max voltage (kv) | Max error | ||
AC | DC | AC | DC | |
DCV-50 | 50 | 70 | 1%RDG+0.1%FS | 0.5%RDG+0.05%FS |
DCV-100 | 100 | 140 | 1%RDG+0.1%FS | 0.5%RDG+0.05%FS |
DCV-150 | 150 | 200 | 1%RDG+0.1%FS | 0.5%RDG+0.05%FS |
DCV-200 | 200 | 300 | 1%RDG+0.1%FS | 0.5%RDG+0.05%FS |
DCV-300 | 300 | 420 | 1%RDG+0.1%FS | 0.5%RDG+0.05%FS |
DCV-400 | 400 | 560 | 1%RDG+0.1%FS | 0.5%RDG+0.05%FS |
DCV-500 | 500 | 700 | 1%RDG+0.1%FS | 0.5%RDG+0.05%FS |
Environment temperature: 0~50°C Humidity: ≤80%RH | ||||
Resistance and capacitor value: Customize | ||||
Compose mode: Customize (Resistive or capacitive) |
Home Products About Us News FAQ Factory Show Download Contact Us
No. 1, Jianlong N. Rd., Jiulongpo District,Jiulong Industrial Park, Chongqing, China
sales@topoilpurifier.com
+86-13983391036
topoilpurifier