+86-23-88901306   sales@topoilpurifier.com
Portable Octane and Cetane Meter SX-150
Home » Products » Petroleum Tester » Fuel Oil Testers » Portable Octane and Cetane Meter SX-150

Category List

loading

Share to:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
sharethis sharing button

Portable Octane and Cetane Meter SX-150

  • SX-150

Availability:
Quantity:

Product Description

Product description

Whether in the field or in the laboratory,this analyzers are leaders in portable rapid analysis instruments. We designs and produces analytical instruments for petrol/gasoline, diesel fuel, kerosene.

Portable octane and cetane analyzers are often used for on-site analysis of octane number of power gasoline, corresponding to the motor method and research method (RON and MON), and also suitable for cetane number analysis of diesel. In addition, the temperature of the analyzed liquid and the freezing point of diesel can also be measured, and the measurement results are displayed on the LCD liquid crystal display.

Octane and cetane analyzer is widely used all over the world. Its measurement method conforms to international standards: octane measurement conforms to: ASTM D 2699-86, ASTM D 2700-86; diesel cetane measurement conforms to: ASTM D 4737- 03, ASTM D 613, EN ISO 5165.

 

Function

1. Determining octane numbers for motor petrols;

2. Determining cetane numbers for diesel fuels;

3. Determining solidification temperature and diesel fuel type;

4. Content of kerosene in diesel fuel;

5. Petrol breakdown time (oxidative stability);

 

Measuring principle

The principle of Octane Meter operation is in determining knock characteristic of gasoline, self-flammability of diesel fuel based on measurements of their dielectric permeability.

 

 

 

Technical specifications

#

Parameter description

Measurement units

Value

1

Measured petrols octane numbers range

ON

40-135

2

Acceptable limit of octane number measurement basic error, max

ON

±0.5

3

Limit of acceptable difference between parallel octane number measurements, max

ON

±0.2

4

Petrol oxidation breakdown time measurement range

Min

50-2400

5

Acceptable basic error limit of petrol oxidation breakdown time

min

10

6

Cetane numbers measurement range

CN

20-100

7

Acceptable basic error limit of cetane numbers, max

CN

±1.0

8

Acceptable difference limit between cetane numbers parallel measurements, max

 

CN

 

± 0.5

9

Acceptable error limit when determining diesel-fuel pour point

ºC

5

10

Kerosene content determination range in diesel fuels

%

0-95

11

Acceptable basic error limit when determining kerosene content in diesel fuels

 

%

 

3

12

Measurement time

sec

1–5

13

Insufficient power supply indication operation threshold

V

5.4

14

Instrument useful life

Minimum years

6

15

Overall dimensions of:




electronic module

mm

100×210×40


sensor #1

mm

60×100


Instrument weight

g

680


Previous: 
Next: 

ABOUT US

Chongqing TOP Tester Co.,LTD belongs to Chongqing TOP Group which is located at Chongqing city--a southwest electromechanical manufacturing center as well as national municipality. We are a sci-tech enterprise and integrate development, design and manufacture. 

QUICK LINKS

PRODUCT CATEGORY

GET IN TOUCH

  No. 1, Jianlong N. Rd., Jiulongpo District,Jiulong Industrial Park,  Chongqing, China

  sales@topoilpurifier.com

  +86-13983391036 

  topoilpurifier

 +86-13983391036

Copyright © 2021 Chongqing TOP Tester Co., Ltd. Sitemap