+86-23-88901306   sales@topoilpurifier.com
Portable Octane and Cetane Meter SX-300
Home » Products » Petroleum Tester » Fuel Oil Testers » Portable Octane and Cetane Meter SX-300

Category List

loading

Share to:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
sharethis sharing button

Portable Octane and Cetane Meter SX-300

  • SX-300

Availability:
Quantity:

Product Description

Product description

     Whether in the field or in the laboratory,this analyzers are leaders in portable rapid analysis instruments. We designs and produces analytical instruments for gasoline, diesel, motor oil and transformer oil.

    Portable octane and cetane analyzers are often used for on-site analysis of octane number of power gasoline, corresponding to the motor method and research method (RON and MON), and also suitable for cetane number analysis of diesel. In addition, the temperature of the analyzed liquid and the freezing point of diesel can also be measured, and the measurement results are displayed on the LCD liquid crystal display.

Octane and cetane analyzer is widely used all over the world. Its measurement method conforms to international standards: octane measurement conforms to: ASTM D 2699-86, ASTM D 2700-86; diesel cetane measurement conforms to: ASTM D 4737- 03, ASTM D 613, EN ISO 5165.

 

Function

1. Determining octane numbers for motor petrols;

2. Determining cetane numbers for diesel fuels;

3. Determining solidification temperature and diesel fuel type;

4. Content of antiknock compounds boosting the octane number of petrols;

5. Content of pour-point depressants for diesel fuels;

6. Content of kerosine in summer diesel fuel;

7. Petrol breakdown time (oxidative stability);

8. Loss angle tangent of circuit-breaker, machine and engine oil;

9. Level of engine, machine and circuit-breaker oil clarity;

10. Manufacturer, engine oil brand;

11. Engine oil base number;

12. Dielectric permeability of oil products;

13. Oil products volume resistivity;

14. Determining the mechanical impurities content in oil products;

15. Determining the cut. GOST 14203-69 – Oil and oil products. Dielectric humidity measuring method.

 

Measuring principle

The principle of Octane Meter operation is in determining knock characteristic of gasoline, self-flammability of diesel fuel and in determining oil characteristics based on measurements of its dielectric permeability and volume resistivity.

 

Technical specifications

#

Parameter description

Measurement units

Value

1

Measured petrols octane numbers range

ON

40-135

2

Acceptable limit of octane number measurement basic error, max

ON

±0.5

3

Limit of acceptable difference between parallel octane number measurements, max

ON

±0.2

4

The determination range of antiknock additives content in petrols

%

0.5-15

5

Acceptable basic error limit of antiknock additives content determination in petrols

%

0.1

6

Petrol oxidation breakdown time measurement range

Min

50-2400

7

Acceptable basic error limit of petrol oxidation breakdown time

%

5

8

Petrol quality determination mode basing on volume resistivity

 

Ohm

10 6-10 14

9

Acceptable basic error limit of volume resistivity measurements

 

%

3

10

Cetane numbers measurement range

CN

20-100

11

Acceptable basic error limit of cetane numbers, max

CN

±1.0

12

Acceptable difference limit between cetane numbers parallel measurements, max

 

CN

 

± 0.5

13

Acceptable error limit when determining diesel-fuel pour point

ºC

2

14

Kerosine content determination range in summer diesel fuels

%

0-50

15

Acceptable basic error limit when determining kerosene content in diesel fuels

 

%

 

3

16

Mode for pour point depressants content determination for diesel fuel

%

0.2-1

17

Acceptable basic error limit when determining of pour point depressants content

%

0.01

18

Motor oils clarity level measurement range

%

50-100

19

Acceptable error limit of motor oils clarity level measurement

%

0.1

20

Acceptable difference limit between motor oils clarity parallel measurements

%

0.01

21

POL dielectric permeability measurement range

units

1-5

22

Acceptable error limit of dielectric permeability measurement, max

unit

0.001

23

Acceptable difference limit between POL dielectric permeability parallel measurements, max

unit

0.001

24

Oils base number determination range

unit

3-24

25

Acceptable basic error limit when determining oils basic number

BN unit

1

26

Motor oils manufacturer and brand determination

Manufacturer

-

27

Circuit-breaker oils (dielectrics) breakdown voltage measurement range

kV

5–100

28

Acceptable error limit of circuit-breaker oils breakdown voltage measurement, max

kV

1

29

Acceptable difference limit between circuit-breaker oils breakdown time parallel measurements, max

kV

0.2

30

Measurement range of circuit-breaker oils loss angle tangent

%

0.01–40

31

Acceptable error limit of circuit-breaker oils loss angle tangent, max

%

0.01

32

Acceptable difference limit between circuit-breaker oils loss angle tangent parallel measurements, max

units

0.001

33

Determination range for mechanical impurities content in oil products

%

97-100

34

Acceptable basic error limit when determining mechanical impurities content in oil products

%

0.01

35

Water-in-oil content determination range for oil products

%

0-30

36

Acceptable basic error limit when determining water-in-oil content of oil products

%

1

37

Measurement time

sec

1–5

38

Insufficient power supply indication operation threshold

V

5.4

39

Instrument useful life


6

40

Overall dimensions of:




electronic module

mm

100х210х40


sensor #1 and #2

mm

60х100


Instrument mass with one sensor/two sensors

g

850 / 680


Previous: 
Next: 

ABOUT US

Chongqing TOP Tester Co.,LTD belongs to Chongqing TOP Group which is located at Chongqing city--a southwest electromechanical manufacturing center as well as national municipality. We are a sci-tech enterprise and integrate development, design and manufacture. 

QUICK LINKS

PRODUCT CATEGORY

GET IN TOUCH

  No. 1, Jianlong N. Rd., Jiulongpo District,Jiulong Industrial Park,  Chongqing, China

  sales@topoilpurifier.com

  +86-13983391036 

  topoilpurifier

 +86-13983391036

Copyright © 2021 Chongqing TOP Tester Co., Ltd. Sitemap